- Introduction
- Parameters
·Adopt high quality high sensitive PIN
optical detector and gallium arsenide RF amplification module to ensure low
noise, low distortion, high capability and reliability.
·Optical power level indicator light can
display in the level of -7dBm, -6dBm, -5dBm, -4dBm, -3dBm, -2dBm, -1dBm, 0dBm,
+1dBm, +2dBm which is convenient for technician to inspect and maintain.
·Adopt wide range, low heating power switch
to meet the different need of voltage in different workplace.
·Controlled by optical AGC, when input
optical power is -7-+2dBm, output power level and CTB, CSO remain unchanged.
·New type aluminum cast waterproof case, can
install in case or steel wire.
·Ensure electromagnetic shielding and
radiating capability of the optical receiver.
·Equalizer and attenuator are successive
adjustable.
·Double power output to ensure superior
nonlinear index.
·60VAC independent power supply.
·Tap or splitter output optional.
ITEM |
UNIT |
PARAMETER |
Operating Bandwidth |
MHz |
45-862/1000 |
Optical Operating Wavelength |
nm |
1290-1600 |
Input Optical Power Range |
dBm |
-9 - +3 |
Optical AGC Range |
dBm |
-7 - +2 |
Optical Return Loss |
dB |
≥45 |
Equivalent Noise Coefficient |
PA√HZ |
≤8 |
Flatness |
dB |
≤±1.0 |
Return Loss |
dB |
≥14 |
RF Input Impedance |
Ω |
75 |
CNR |
dB |
≥51 |
ITEM |
UNIT |
PARAMETER |
CTB |
dB |
≥65 |
CSO |
dB |
≥60 |
Nominal Output Power Level |
dBuV |
108 |
Output Test Port Power Level |
dBuV |
-20 |
Input Voltage Range |
VAC |
35-90/140-265 |
Operating Temperature |
℃ |
-40 - +60 |
Consumption |
W |
<20 |
Dimension ( Include Head F) |
mm |
230(L)*145(W)*95(H) |